Power Supply Voltage: 117 VAC, 50-60 Hz
Power Supply Current Consumption: 120 VA
Rotor Voltage: 24 VAC
Cable Conductors Required: 6 and 6
Rotation Time (Non Loaded): Elevation (180°): 67 sec at 60 Hz
0 Azimuth (360°): 58 sec at 60 Hz
Rotation Range: Elevation: 180°
0 Azimuth: 450°
Rotation Torque: Elevation: 101 foot-pounds (1,400 kgf-cm)
0 Azimuth: 44 foot-pounds (600 kgf-cm)
Braking Torque: Elevation : 289 foot-pounds (4,000 kgf-cm)
0 Azimuth: 289 foot-pounds (4,000 kgf-cm)
Maximum Vertical Load: Elevation: 30 kg or less
0 Azimuth: 440 Lbs. (200 kg) or less
Mast Outside Diameter: 1.5-2.5 inches (38 to 63mm)
Boom Outside Diameter: 1.24-1.675 inches (32 to 43mm)
Braking Type: Mechanical and Electrical stoppers
Wind Loading Area: 1.0 m2 or less
Maximum Continuous Duty: 5 minutes
Operating Temperature Range: 0°C to +40°C (Controller)
0 -20°C to +40°C (Rotator)
Rotator Dimension: 10 x 13.75 x 7.5 inches
Rotator Weight: 20 lbs (9 kg)
Controller Dimension (WHD): 200 x 130 x 193 mm
Controller Weight: 6.6 lbs. (3 kg)
0
Specifications are subject to change without notice or obligation.